EA 229: the short version
EA 229 is not the same as EA 227: here the flame was established and then lost. Look first at drainage and the flue. Some causes are simple to rule out, others need a Gas Safe-registered engineer.
Codes can differ between models, so look at the fault table in your user manual too. Our engineers cover B90 to B94 and the villages around them.
Checks that are safe to do
1. Look at the condensate pipe outside
Every modern boiler has a small plastic condensate pipe, and outdoor sections freeze in a cold snap. A frozen pipe can make the boiler gurgle before it shuts down. Provided you can reach the pipe safely from the ground, thaw it with warm water, never boiling, poured slowly along the pipe, then reset the boiler. Leave pipes at height to an engineer.
2. Glance at the flue terminal
Make certain the flue terminal outside is not covered or blocked. Do not touch, remove or alter any part of the flue: any damage or blockage is a job for a Gas Safe-registered engineer.
3. Look at the gas supply
Try the gas hob, if you have one. Prepayment customers should look at the meter still has credit, since a meter that has run out stops the boiler lighting. Nothing on the gas side of the boiler is a DIY job. If you smell gas, ring 0800 111 999 from outside the property.
4. Use the reset button, once
Press the reset button as your user manual describes: Worcester Bosch asks you to hold it for about five seconds. Give it a handful of minutes to run through its start-up. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.
Do not open the boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and ring 0800 111 999.
What can trigger EA 229
In our experience, and in the manufacturer's own guidance, the usual causes are:
- A worn flame-sensing electrode
- Strong wind or an obstruction at the flue terminal
- A frozen or blocked condensate pipe or trap
- An interruption in the gas supply
When to get help
If EA 229 keeps coming back, an engineer needs to look at the flame-sensing circuit, condensate trap and flue: the trap sits inside the casing, which is engineer territory.