Worcester Bosch D5: condensate pump fault (floor-standing)

The display on your Worcester Bosch is showing D5. This page explains the code, the checks you can safely make and when you need us.

  • Gas Safe registered
  • Itemised written quotes
  • Care for your home

Speak with an engineer

It helps to have the boiler's make, model and any error code to hand.

0121 562 1812

Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

D5: the short version

On floor-standing Worcester Bosch boilers, such as the Greenstar Highflow CDi and FS CDi, D5 is a condensate pump fault. Worcester also says a frozen condensate pipe can show as EA or D5, depending on the boiler. Other models may use D5 differently, so look at the manual for yours. There are a handful of safe checks to try first, but repeat lockouts need an engineer.

Meanings vary a little between models; your manual has the definitive list. Larger homes in Knowle and Dorridge often run a system boiler with a hot water cylinder, so a fault can show up as no hot water even when the heating seems fine.

Checks that are safe to do

1. Look at the condensate pipe outside

Condensing boilers drain water through a plastic pipe, normally white or grey, that often runs outside to a drain. If it is frozen, the boiler may gurgle and then lock out. As long as the pipe is low down and safe to reach, thaw it with a hot water bottle or warm, not boiling, water from a watering can, then reset the boiler. Never climb a ladder to do this.

2. Use the reset button, once

Follow the reset steps in your manual: on a Greenstar, hold it for around five seconds. Allow a little time for the boiler to try again. If it locks out again, do not keep pressing: repeated resets can hide a fault that needs proper attention.

3. Note the code and model

Note the exact code first, plus the make and model from the label on the boiler, and anything unusual you noticed, such as noises or a leak. That information helps us diagnose faster.

Do not open the boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and ring 0800 111 999.

What can trigger D5

The manufacturer's fault table and day-to-day experience point to:

  • A kinked or blocked condensate hose
  • A failed or blocked condensate pump
  • A frozen or blocked external condensate pipe

When to get help

When thawing does not help, the condensate pump needs cleaning or replacing: it sits inside the boiler casing.

If it will not clear, call 0121 562 1812 or book a visit online. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Other codes worth knowing

Questions

Does D5 mean the same on every Worcester boiler?

No. It is documented as a condensate pump fault on floor-standing models; other models may differ, so look at your manual.

Can you fix a Worcester Bosch boiler in Solihull?

We do. We work on Worcester Bosch boilers all over Solihull, from Knowle to Monkspath. Call 0121 562 1812 with the code.

A heating problem in Solihull?

Telephone us and an engineer will talk it through with you.

TelephoneEnquire