Worcester Bosch EA 227: no flame detected at ignition

Your Worcester Bosch has stopped and the display says EA 227. This page explains the code, the checks you can safely make and when you need us.

  • Gas Safe registered
  • Itemised written quotes
  • Care for your home

Speak with an engineer

It helps to have the boiler's make, model and any error code to hand.

0121 562 1812

Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

EA 227: the short version

EA 227 is Worcester's most common lockout: the boiler attempted ignition and never sensed a flame. Worcester suggests checking the gas is on, the condensate pipe is not frozen and the flue outlet is clear. Try the simple checks below first; if the code returns, ring an engineer.

Always cross-check with the manual for your exact model. Families in Knowle and Elmdon tend to notice a boiler fault first as a lukewarm shower in the morning rush.

Checks that are safe to do

1. Rule out the gas supply

Try the gas hob, if you have one. On a prepayment meter, look at the credit and any emergency credit, as running out is a common cause of ignition lockouts. Do not touch any gas pipes or valves on or inside the boiler. If you smell gas, get everyone out and ring 0800 111 999.

2. Look for a frozen condensate pipe

The condensate pipe is the plastic pipe that carries water from the boiler to a drain, often outside. If it is frozen, the boiler may gurgle and then lock out. Provided you can reach the pipe safely from the ground, thaw it with a warm cloth or warm (not boiling) water, then reset the boiler. Leave pipes at height to an engineer.

3. Glance at the flue terminal

From outside, check that nothing obvious is blocking the flue terminal, such as plants, a cover or a nest. Never take apart or adjust the flue yourself: any damage or blockage is a job for a Gas Safe-registered engineer.

4. Reset the boiler once

Use the reset button on the front panel: on a Greenstar, hold it for around five seconds. Wait two or three minutes for it to restart. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.

Do not open the boiler casing, and leave anything on the gas side alone. If there is a smell of gas, ring 0800 111 999 from outside.

What can trigger EA 227

In our experience, and in the manufacturer's own guidance, the usual causes are:

  • A gas valve or PCB fault
  • A worn ignition or flame-sensing electrode
  • A frozen or blocked condensate pipe
  • A blocked flue outlet
  • Gas off or a prepayment meter with no credit

When to get help

If the gas is on, the condensate is clear and EA 227 still returns, ring an engineer: which only a Gas Safe-registered engineer should do.

If it will not clear, call 0121 562 1812 or book a visit online. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Other codes worth knowing

Questions

Can a frozen condensate pipe cause EA 227?

Yes. Worcester Bosch lists a frozen condensate pipe as a cause of the EA code. Thaw it safely with warm, not boiling, water if it is at ground level, then reset.

Do you repair Worcester Bosch boilers in Solihull?

We do. Our Gas Safe-registered engineers repair Worcester Bosch boilers across B90 to B94, including Catherine-de-Barnes and Hampton-in-Arden. Call 0121 562 1812 with the code.

A heating problem in Solihull?

Telephone us and an engineer will talk it through with you.

TelephoneEnquire