Skip to main content
0121 562 1812

Vaillant · F.28

Vaillant F.28: ignition failure at start-up

F.28 has appeared on your Vaillant boiler. Below: the meaning, the likely causes and the point at which to stop and call.

  • Gas Safe registered
  • Itemised written quotes
  • Care for your home

Speak with an engineer

It helps to have the boiler's make, model and any error code to hand.

0121 562 1812

Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

F.28: the short version

F.28 is Vaillant's start-up ignition lockout: the boiler tried to light but never saw a flame. Vaillant's own manual says it shows after five unsuccessful ignition attempts, at which point it shuts the gas off and waits. Try the simple checks below first; if the code returns, ring an engineer.

Codes can differ between models, so look at the fault table in your user manual too. We are regularly in Catherine-de-Barnes, Hampton-in-Arden and Dickens Heath, where the same handful of codes come up again and again.

Checks that are safe to do

1. Rule out the gas supply

See whether another gas appliance, such as the hob, lights. Prepayment customers should look at the meter still has credit, as running out is a common cause of ignition lockouts. Nothing on the gas side of the boiler is a DIY job. If you smell gas, leave the property and ring the National Gas Emergency Service on 0800 111 999.

2. In freezing weather, look at the condensate pipe

Condensing boilers drain water through a plastic pipe, normally white or grey, that often runs outside to a drain. A frozen pipe can make the boiler gurgle before it shuts down. As long as the pipe is low down and safe to reach, thaw it with a hot water bottle or warm, not boiling, water from a watering can, then reset the boiler. Never climb a ladder to do this.

3. Try a single reset

Follow the reset steps in your manual: Vaillant asks you to hold it for longer than three seconds, with a maximum of three tries. Wait two or three minutes for it to restart. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.

Do not open the boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and ring 0800 111 999.

What can trigger F.28

In our experience, and in the manufacturer's own guidance, the usual causes are:

  • Low gas pressure from the supply
  • A frozen or blocked condensate pipe
  • A worn ignition or flame-sensing electrode
  • Gas turned off or a prepayment meter out of credit
  • A faulty gas valve, wiring or PCB

When to get help

Vaillant suggests a maximum of three resets before getting help. Anything involving the gas valve, gas pressure or electrodes needs a Gas Safe engineer.

Ring 0121 562 1812 with the code and your boiler's model, or use our enquiry form. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Other codes worth knowing

Questions

Is F28 dangerous?

The code is the boiler protecting you, so the boiler is shut down safely. Do not open the casing or try to adjust anything on the gas side; if you smell gas, ring 0800 111 999.

Can you fix a Vaillant boiler in Solihull?

Yes. Our Gas Safe-registered engineers repair Vaillant boilers across B90 to B94, including Bentley Heath and Hockley Heath. Call 0121 562 1812 with the code.

A heating problem in Solihull?

Telephone us and an engineer will talk it through with you.

TelephoneEnquire