F.28: the short version
F.28 is Vaillant's start-up ignition lockout: the boiler tried to light but never saw a flame. Vaillant's own manual says it shows after five unsuccessful ignition attempts, at which point it shuts the gas off and waits. Try the simple checks below first; if the code returns, ring an engineer.
Codes can differ between models, so look at the fault table in your user manual too. We are regularly in Catherine-de-Barnes, Hampton-in-Arden and Dickens Heath, where the same handful of codes come up again and again.
Checks that are safe to do
1. Rule out the gas supply
See whether another gas appliance, such as the hob, lights. Prepayment customers should look at the meter still has credit, as running out is a common cause of ignition lockouts. Nothing on the gas side of the boiler is a DIY job. If you smell gas, leave the property and ring the National Gas Emergency Service on 0800 111 999.
2. In freezing weather, look at the condensate pipe
Condensing boilers drain water through a plastic pipe, normally white or grey, that often runs outside to a drain. A frozen pipe can make the boiler gurgle before it shuts down. As long as the pipe is low down and safe to reach, thaw it with a hot water bottle or warm, not boiling, water from a watering can, then reset the boiler. Never climb a ladder to do this.
3. Try a single reset
Follow the reset steps in your manual: Vaillant asks you to hold it for longer than three seconds, with a maximum of three tries. Wait two or three minutes for it to restart. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.
Do not open the boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and ring 0800 111 999.
What can trigger F.28
In our experience, and in the manufacturer's own guidance, the usual causes are:
- Low gas pressure from the supply
- A frozen or blocked condensate pipe
- A worn ignition or flame-sensing electrode
- Gas turned off or a prepayment meter out of credit
- A faulty gas valve, wiring or PCB
When to get help
Vaillant suggests a maximum of three resets before getting help. Anything involving the gas valve, gas pressure or electrodes needs a Gas Safe engineer.
Ring 0121 562 1812 with the code and your boiler's model, or use our enquiry form. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.