F.29: the short version
With F.29 the burner did light, then lost its flame during operation and failed to re-ignite. It does not always mean a part has failed. Try the simple checks below first; if the code returns, ring an engineer.
Meanings vary a little between models; your manual has the definitive list. In a family home in Dorridge the boiler may be in a garage or utility room, where pipes and condensate lines are colder than the rest of the house.
Checks that are safe to do
1. Make certain gas is reaching the house
See whether another gas appliance, such as the hob, lights. Prepayment customers should look at the meter still has credit, since a meter that has run out stops the boiler lighting. Nothing on the gas side of the boiler is a DIY job. If you smell gas, get everyone out and ring 0800 111 999.
2. In freezing weather, look at the condensate pipe
Every modern boiler has a small plastic condensate pipe, and outdoor sections freeze in a cold snap. When it freezes the boiler often gurgles and stops. As long as the pipe is low down and safe to reach, thaw it with a warm cloth or warm (not boiling) water, then reset the boiler. Never climb a ladder to do this.
3. Glance at the flue terminal
From outside, check that nothing obvious is blocking the flue terminal, such as plants, a cover or a nest. Looking is fine; adjusting the flue is not: any damage or blockage is a job for a Gas Safe-registered engineer.
4. Use the reset button, once
Press the reset button as your user manual describes: Vaillant asks you to hold it for longer than three seconds, with a maximum of three tries. Give it a handful of minutes to run through its start-up. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.
Do not open the boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and ring 0800 111 999.
What can trigger F.29
In our experience, and in the manufacturer's own guidance, the usual causes are:
- An ignition or flame-sensing fault
- A brief interruption in the gas supply
- A poor electrical earth
- Condensate backing up because of a frozen or blocked pipe
- Flue gases being drawn back in at the terminal
When to get help
If F.29 returns after a reset, or happens regularly, the boiler needs investigating: our engineer will check gas pressure, the flue and the earth bonding.
Ring 0121 562 1812 with the code and your boiler's model, or use our enquiry form. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.