Worcester Bosch · E9 224

Worcester Bosch E9 224: overheat safety thermostat

The display on your Worcester Bosch is showing E9 224. Below: the meaning, the likely causes and the point at which to stop and call.

  • Gas Safe registered
  • Itemised written quotes
  • Care for your home

Speak with an engineer

It helps to have the boiler's make, model and any error code to hand.

0121 562 1812

Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

E9 224: the short version

E9 224 is an overheat lockout. It shows the boiler got hotter than it should, so it shut down. There are a handful of safe checks to try first, but repeat lockouts need an engineer.

Codes can differ between models, so look at the fault table in your user manual too. Larger homes in Knowle and Dorridge often run a system boiler with a hot water cylinder, so a fault can show up as no hot water even when the heating seems fine.

Checks that are safe to do

1. Look at the pressure

Once the system has cooled down, read the pressure display on the front of the boiler. The majority of boilers want about 1 to 1.5 bar when cold, or whatever figure your manual gives. If it reads under 1 bar, you can normally top it up yourself using the filling loop, a short braided hose or a built-in key under the boiler. Open the valves slowly, watch the needle rise, then close them firmly once you reach the right pressure. If you find yourself topping up every week, water is escaping somewhere and it needs an engineer to trace it.

2. Bleed the radiators

Trapped air upsets circulation and can make the boiler overheat. With the heating off and the radiators cool, use a radiator key to open each bleed valve until water appears, then close it. Recheck the pressure when you have finished, as it will have dropped.

3. Try a single reset

Use the reset button on the front panel: Worcester Bosch asks you to hold it for about five seconds. Give it a handful of minutes to run through its start-up. If it locks out again, do not keep pressing: repeated resets can hide a fault that needs proper attention.

Anything behind the casing, and any gas or flue work, must be left to a Gas Safe-registered engineer. If you smell gas, leave the property and ring the National Gas Emergency Service on 0800 111 999.

What can trigger E9 224

The manufacturer's fault table and day-to-day experience point to:

  • Low pressure or air in the system
  • Sludge or scale in the heat exchanger
  • A flue or sensor fault
  • Poor circulation from a sticking pump

When to get help

If E9 224 returns, leave the boiler off: an engineer needs to find out why it is overheating.

Need a hand in Solihull? Call 0121 562 1812 or send us the details and we will call you back. We are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Other codes worth knowing

Questions

What causes a Worcester Bosch to overheat?

Normally poor circulation: a sticking pump, sludge, low pressure or air. Less often a flue or sensor fault.

Can you fix a Worcester Bosch boiler in Solihull?

We do. We work on Worcester Bosch boilers all over Solihull, from Dickens Heath to Catherine-de-Barnes. Call 0121 562 1812 with the code.