Baxi E125: circulation fault

E125 has appeared on your Baxi boiler. This page explains the code, the checks you can safely make and when you need us.

  • Gas Safe registered
  • Itemised written quotes
  • Care for your home

Speak with an engineer

It helps to have the boiler's make, model and any error code to hand.

0121 562 1812

Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

E125: the short version

E125 tells you the boiler cannot detect proper water circulation. Baxi notes it can follow E193, a circulation warning that becomes E125 if it persists. There are a handful of safe checks to try first, but repeat lockouts need an engineer.

Meanings vary a little between models; your manual has the definitive list. Solihull homes range from 1930s semis to brand-new builds, so we will always look at the make and model before guessing at a cause.

Checks that are safe to do

1. Let trapped air out of the radiators

Air in the system stops water circulating properly. With everything cold, use a radiator key to open each bleed valve until water appears, then close it. Afterwards, look at the pressure again, because bleeding lets water out.

2. Look at the pressure display

With the heating off and the boiler cool, read the pressure display on the front of the boiler. The majority of boilers want around 1 to 1.5 bar when cold, though the manual for your boiler is the final word. If it reads lower than that, you can normally refill it yourself using the filling loop or filling key, which is normally underneath the boiler. Open the valves slowly, watch the needle rise, then shut both valves properly once you reach the right pressure. If it falls again soon after, water is escaping somewhere and that is a job for an engineer.

3. Reset the boiler once

Press the reset button as your user manual describes: Baxi's reset steps depend on the model, so follow your user guide. Give it a handful of minutes to run through its start-up. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.

Do not open the boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and ring 0800 111 999.

What can trigger E125

In our experience, and in the manufacturer's own guidance, the usual causes are:

  • A pump that is sticking or failing
  • Sludge or a blocked filter
  • Air in the system
  • Low pressure

When to get help

Persistent E125 points to the pump or sludge.

Ring 0121 562 1812 with the code and your boiler's model, or use our enquiry form. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Other codes worth knowing

Questions

Can sludge cause E125?

Yes. Sludge and debris restrict flow. An engineer can clean the filter or system.