F.62: the short version
F.62 means the boiler noticed the flame signal fading too slowly after it told the gas valve to close. The causes Vaillant gives are the gas valve, the electrode or the PCB. This is not a DIY fault.
Meanings vary a little between models; your manual has the definitive list. Larger homes in Knowle and Dorridge often run a system boiler with a hot water cylinder, so a fault can show up as no hot water even when the heating seems fine.
What you can do
1. Note the code and model
Before you do anything else, write down the full code, along with the model name printed on the front or underneath, and whether it happened on heating, hot water or both. That information helps us diagnose faster.
2. Use the reset button, once
Follow the reset steps in your manual: on Vaillant ecoTEC models you hold it for more than three seconds, and Vaillant suggests no more than three attempts. Wait two or three minutes for it to restart. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.
Never remove the boiler casing or touch the gas valve, gas pipes or flue. If there is a smell of gas, ring 0800 111 999 from outside.
What can trigger F.62
Possible causes include:
- A defective PCB
- The ignition and monitoring electrode
- A gas valve that isn't closing cleanly
When to get help
This code relates to gas shut-off, so do not keep using a boiler that repeats it: after one reset, leave it off and book an engineer.
Need a hand in Solihull? Call 0121 562 1812 or send us the details and we will call you back. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.