Worcester Bosch CE 207: low water pressure

CE 207 has appeared on your Worcester Bosch boiler. This page explains the code, the checks you can safely make and when you need us.

  • Gas Safe registered
  • Itemised written quotes
  • Care for your home

Speak with an engineer

It helps to have the boiler's make, model and any error code to hand.

0121 562 1812

Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

CE 207: the short version

CE 207 means the system water pressure has fallen too low for the boiler to run. Worcester's figure is 1 to 1.5 bar with the system cool. On some newer Worcester models with a text display, low pressure is shown as a number with a description instead. Good news: this code is often a homeowner fix.

Always cross-check with the manual for your exact model. We are regularly in Dorridge, Knowle and Elmdon, where the same handful of codes come up again and again.

Checks that are safe to do

1. Look at the pressure

Once the system has cooled down, read the pressure display on the front of the boiler. Most boilers want around 1 to 1.5 bar when cold, but your user manual gives the figure for your model. If it reads under 1 bar, you can normally top it up yourself using the filling loop or filling key, which is normally underneath the boiler. Open the valves slowly, watch the needle rise, then shut both valves properly once you reach the right pressure. If it falls again soon after, water is escaping somewhere and that leak needs finding.

2. Use the reset button, once

Follow the reset steps in your manual: Worcester Bosch asks you to hold it for about five seconds. Give it a handful of minutes to run through its start-up. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.

Do not open the boiler casing, and leave anything on the gas side alone. If there is a smell of gas, ring 0800 111 999 from outside.

What can trigger CE 207

In our experience, and in the manufacturer's own guidance, the usual causes are:

  • A slow leak somewhere on the system
  • An expansion vessel that needs recharging
  • Pressure lost after bleeding radiators
  • The pressure relief valve discharging

When to get help

A repeat CE 207 means a leak or a component fault: look for drips under radiators and a dribbling pipe outside, then ring us.

Ring 0121 562 1812 with the code and your boiler's model, or use our enquiry form. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Other codes worth knowing

Questions

Why does CE 207 keep coming back?

Water is leaving the system, through a leak, the relief valve or because the expansion vessel has lost its charge. An engineer can trace it.

Do you work on Worcester Bosch boilers around Solihull?

Yes. We work on Worcester Bosch boilers all over Solihull, from Elmdon to Cheswick Green. Call 0121 562 1812 with the code.